Lens Meter Maintenance and Trouble-shooting

Lens Meter Maintenance and Trouble-shooting

October 10, 2024
Maintenance
(1)Don’t put machine under sunshine.
(2)Don’t put heavy part on machine, which will damage to machine.
(3)To keep clean both machine and air around.
(4)To keep machine clean. Don’t use the organic solution like volatile liquid, diluent or benzol to machine.
(5)No operation for long time, to cut off power supply and pull out the plug.
(6)Please prepare a dust-proof cover and cover the instrument when it is free in order to reduce the influence of dust.
(7)Please set screen protection when the instrument is in use, if it is free of test the screen can shut automatically.
(8)Clean the protecting lens regularly. Take down the bracket first and clear the dust or oil with soft brush or lens paper.
Warning:
鈼?nbsp;Don’t scratch the protecting lens, otherwise the precision will be reduced.
鈼?nbsp;lens bracket must place well to avoid measurement mistake.

 

Trouble shooting

NoFaultReasonSolution
1No reaction from screen when turn on
machine
There power wires are not connected well, or turn off machine not correctlyTo check the wires if in good condition, and cut off the power then turn on it after a while.
2The screen doesn’t show anything suddenly.The screen protection has been set.To touch screen and enter into Menu to set a reasonable time for screen protection.
3When power is on, but also can’t switch on the monitor.monitor auto off function is on or monitor brightness volume is lowpress any switch to resume the screen or adjust the brightness volume
4The data is not 0 when there is no lens.The light is too strong or the protecting glass is dirtyTo avoid the strong light or clean the glass
5Not reaction when press the printNo measured data saved.The data should be saved then can be printed.
6The marks on lens not clearThere is problem with the dot pen.To change the dot pen
7Measured data preciselessNeed to calibrate the data againEnter into the interface for calibration
Currency: USD
USD - US Dollar
EUR - Euro
GBP - British Pound
JPY - Japanese Yen
AED - Arab Emir. Dirham
AUD - Australian Dollar
BRL - Brazilian Real
CAD - Canadian Dollar
CHF - Switzerland Francs
DKK - Denmark Kroner
HKD - Hong Kong Dollars
IDR - Indonesia Rupiahs
INR - Indian Rupee
KRW - South Korea Won
MOP - Macau Pataca
MYR - Malaysia Ringgits
NOK - Norwegian Krone
NZD - New Zealand Dollars
PHP - Philippines Pesos
RUB - Russian Ruble
SAR - Saudi Arabia Riyals
SEK - Swedish Krona
THB - Thailand Baht
TRY - Turkey Lira
TWD - Taiwan New Dollars
SGD - Singapore Dollars
Language: English
  1. English
  2. Deutsch
  3. Français
  4. Русский
  5. にほんご
  6. 한국어
  7. Español
  8. Português
  9. Italiano
  10. العربية
  11. Nederlands
  12. Ελληνικά
Need Help?
Chat live with us
Request Quote
Want to call?

86-15160060534

WhatsApp
Track Order
Want to check the status of your order? You can put in your order number and click track order to find the tracking information or login your account to check the detail information.
order number
  • order number
  • tracking number